{"id":"CVE-2026-1495","published":"2026-02-10T20:18:10Z","modified":"2026-02-12T18:46:41Z","title":"Insertion of Sensitive Information into Log File vulnerability in AVEVA PI to CONNECT Agent","vendor":"AVEVA","product":"PI to CONNECT Agent","tier":"tail","description":{"text":"The vulnerability, if exploited, could allow an attacker with Event Log Reader (S-1-5-32-573) privileges to obtain proxy details, including URL and proxy credentials, from the PI to CONNECT event log files. This could enable unauthorized access to the proxy server.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.5,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00133,"percentile":0.02892,"provenance":"source"},"cwes":[{"id":"CWE-532","name":"Insertion of Sensitive Information into Log File"}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-041-04","tags":["government-resource"]}],"priority":{"score":5.1,"factors":[{"name":"EPSS percentile","points":0.58},{"name":"CVSS severity","points":4.55}]},"vendorSlug":"aveva","affectedVersions":[{"vendor":"AVEVA","product":"PI to CONNECT Agent","versions":["<= Version v2.4.2520"]}],"solutions":{"items":["AVEVA recommends that organizations evaluate the impact of this vulnerability based on their operational environment, architecture, and product implementation. * Users of affected product versions should apply security updates to mitigate the risk of proxy details exposure in newly generated PI to CONNECT Agent event logs. * Users who have used affected product versions, should review existing PI to CONNECT Agent event logs (live/backups/copies) for exposed proxy connection details and consider purging the sensitive data from logs and/or configuring new credentials for access to the proxy service. The following general defensive measures are recommended: * Remove use of plain text passwords in proxy URLs. Alternatively, if passwords are required by the proxy, then use least-privilege credentials. * Ensure only trusted users are given Event Log Reader (S-1-5-32-573) privileges on hosts where PI to CONNECT is installed. * Review existing PI to CONNECT event logs (live/backups/copies) for exposed proxy connection details and consider purging the sensitive data from logs and/or configuring new credentials for access to the proxy service. All affected versions can be fixed by…"],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2026-02-12T18:46:32.294842Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-6716","exploited":false,"provenance":"source"}}