{"id":"CVE-2026-1690","published":"2026-01-30T16:32:11Z","modified":"2026-02-23T09:10:09Z","title":"Tenda HG10 formSysCmd system command injection","vendor":"Tenda","product":"HG10","tier":"tail","description":{"text":"A flaw has been found in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. This affects the function system of the file /boaform/formSysCmd. This manipulation of the argument sysCmd causes command injection. The attack may be initiated remotely. The exploit has been published and may be used.","provenance":"source","from":"CVE.org"},"cvss":{"score":4.7,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.04718,"percentile":0.92044,"provenance":"source"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"},{"id":"CWE-74","name":"Improper Neutralization of Special Elements in Output Used by a Downstream Component"}],"references":[{"url":"https://vuldb.com/?id.343484","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.343484","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.741425","tags":["third-party-advisory"]},{"url":"https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSysCmd-sysCmd-command.md","tags":["related"]},{"url":"https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSysCmd-sysCmd-command.md#poc","tags":["exploit"]},{"url":"https://www.tenda.com.cn/","tags":["product"]}],"priority":{"score":26.7,"factors":[{"name":"EPSS percentile","points":18.41},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":3.29}]},"vendorSlug":"tenda","affectedVersions":[{"vendor":"Tenda","product":"HG10","versions":["US_HG7_HG9_HG10re_300001138_en_xpon"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2026-01-30T16:53:41.108984Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"A command injection flaw exists in the system function of the /boaform/formSysCmd component of the Tenda HG10 router firmware (US_HG7_HG9_HG10re_300001138_en_xpon), where manipulation of the sysCmd argument allows injected commands to run. An attacker with network access can exploit it remotely by sending a crafted request, but must first have high-privilege authentication to the device.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T05:38:17Z"},"euvd":{"id":"EUVD-2026-5019","exploited":false,"provenance":"source"},"exploitRefs":["https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSysCmd-sysCmd-command.md#poc"]}