{"id":"CVE-2026-17429","published":"2026-08-19T18:40:44Z","modified":"2026-08-21T16:14:54Z","title":"Power System Incorrect Authorization","vendor":"IBM","product":"Power Systems Firmware","tier":"tail","description":{"text":"IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 - OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can write arbitrary data to hardware control registers, allowing full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.","provenance":"source","from":"CVE.org"},"cvss":{"score":8.1,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00151,"percentile":0.04367,"provenance":"source"},"cwes":[{"id":"CWE-863","name":"Incorrect Authorization"}],"references":[{"url":"https://www.ibm.com/support/pages/node/7283218","tags":["vendor-advisory","patch"]}],"priority":{"score":6.5,"factors":[{"name":"EPSS percentile","points":0.87},{"name":"CVSS severity","points":5.67}]},"vendorSlug":"ibm","affectedVersions":[{"vendor":"IBM","product":"Power Systems Firmware","versions":["FW1120.00",">= FW1110.00, <= FW1110.30",">= FW1060.00, <= FW1060.80",">= FW950.00, <= FW950.H2",">= OP940.00, <= OP940.a1",">= OP940.00, <= OP940.81"]}],"solutions":{"items":["Customers with the products below should install FW1110.31(1110_134), FW1120.01(1120_167), or newer to remediate this vulnerability. Power 11 * IBM Power System E1180 (9080-HEU) Customers with the products below should install FW1110.31(1110_155), FW1120.01(1120_190), or newer to remediate this vulnerability. Power 11 * IBM Power System S1122 (9824-22A) * IBM Power System S1124 (9824-42A) * IBM Power System S1122s (9824-22B) * IBM Power System S1114 (9824-41B) * IBM Power System L1122 (9856-22H) * IBM Power System L1124 (9856-42H) * IBM Power System E1150 (9043-MRU) Customers with the products below should install FW1120.01(1120_190), or newer to remediate this vulnerability. Power 11 * IBM Power System S1112 (9242-21B, 9242-21T) Customers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability. Power 10 * IBM Power System E1080 (9080-HEX) Customers with the products below should install  FW1060.81(1060_191), or newer to remediate this vulnerability. Power 10 * IBM Power System S1022 (9105-22A) * IBM Power System S1024 (9105-42A) * IBM Power System S1022s (9105-22B) * IBM Power System S1014 (9105-41B) * IBM Power System L1022…"],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2026-08-21T16:07:49.479768Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-62685","exploited":false,"provenance":"source"}}