{"id":"CVE-2026-22110","published":"2026-10-30T10:34:24Z","modified":"2026-10-30T16:35:40Z","title":"Missing authentication check on POST/PUT requests","vendor":"Delta Electronics","product":"Delta UFC500","tier":"tail","description":{"text":"The web server does not check authentication on POST or PUT. An unauthenticated attacker can reboot the charger; by brute-forcing the configid, they can also set the service password and then change any setting.","provenance":"source","from":"CVE.org"},"cvss":{"score":8.7,"severity":"HIGH","version":"4.0","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.0024,"percentile":0.15398,"provenance":"source"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"references":[{"url":"https://csirt.divd.nl/DIVD-2026-00012","tags":["third-party-advisory"]},{"url":"https://csirt.divd.nl/CVE-2026-22110","tags":["third-party-advisory"]}],"priority":{"score":9.2,"factors":[{"name":"EPSS percentile","points":3.08},{"name":"CVSS severity","points":6.09}]},"vendorSlug":"delta-electronics","affectedVersions":[{"vendor":"Delta Electronics","product":"Delta UFC500","versions":["< 2.4.18"]},{"vendor":"Delta Electronics","product":"Delta UFC500","versions":["< 4.4.1"]}],"fixedVersions":[{"vendor":"Delta Electronics","product":"Delta UFC500","versions":["2.4.18"]}],"solutions":{"items":["Update to the latest version."],"from":"CVE.org CNA","provenance":"source"},"capec":[{"id":"CAPEC-115","name":"Authentication Bypass"}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2026-10-30T16:35:22.976391Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-113765","exploited":false,"provenance":"source"}}