{"id":"CVE-2026-2227","published":"2026-02-09T10:02:09Z","modified":"2026-02-23T09:59:48Z","title":"D-Link DCS-931L setSystemAdmin doSystem command injection","vendor":"D-Link","product":"DCS-931L","tier":"tail","description":{"text":"A vulnerability was found in D-Link DCS-931L up to 1.13.0. Impacted is the function doSystem of the file /setSystemAdmin. Performing a manipulation of the argument AdminID results in command injection. The attack may be initiated remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.","provenance":"source","from":"CVE.org"},"cvss":{"score":4.7,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.06829,"percentile":0.94168,"provenance":"source"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"},{"id":"CWE-74","name":"Improper Neutralization of Special Elements in Output Used by a Downstream Component"}],"references":[{"url":"https://vuldb.com/?id.344944","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.344944","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.753450","tags":["third-party-advisory"]},{"url":"https://vuldb.com/?submit.753980","tags":["third-party-advisory"]},{"url":"https://github.com/cha0yang1/CVE/blob/main/D-Link%20DCS931L1.md","tags":["exploit"]},{"url":"https://www.dlink.com/","tags":["product"]}],"priority":{"score":27.1,"factors":[{"name":"EPSS percentile","points":18.83},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":3.29}]},"vendorSlug":"d-link","affectedVersions":[{"vendor":"D-Link","product":"DCS-931L","versions":["1.0","1.1","1.2","1.3","1.4","1.5","1.6","1.7","1.8","1.9"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2026-02-09T13:51:41.527061Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"The D-Link DCS-931L (up to version 1.13.0) contains a command injection flaw in the doSystem function reached via the /setSystemAdmin endpoint, where the AdminID argument is not properly neutralised. An attacker with network access and high-privilege authentication (PR:H) can inject operating system commands through that argument, and the attack requires no user interaction.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T05:37:57Z"},"euvd":{"id":"EUVD-2026-6607","exploited":false,"provenance":"source"},"exploitRefs":["https://github.com/cha0yang1/CVE/blob/main/D-Link%20DCS931L1.md"]}