{"id":"CVE-2026-25656","published":"2026-02-10T09:58:55Z","modified":"2026-04-14T08:40:44Z","title":"A vulnerability has been identified in SINEC NMS (All versions < V4.0 SP3), User Management Component (UMC) (All…","vendor":"Siemens","product":"SINEC NMS","tier":"tail","description":{"text":"A vulnerability has been identified in SINEC NMS (All versions < V4.0 SP3), User Management Component (UMC) (All versions < V2.15.2.1). The affected application permits improper modification of a configuration file by a low-privileged user.\r\nThis could allow an attacker to load malicious DLLs, potentially leading to arbitrary code execution with SYSTEM privileges.(ZDI-CAN-28108)","provenance":"source","from":"CVE.org"},"cvss":{"score":7.8,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00264,"percentile":0.18682,"provenance":"source"},"cwes":[{"id":"CWE-427","name":"Uncontrolled Search Path Element"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-311973.html","tags":[]}],"priority":{"score":9.2,"factors":[{"name":"EPSS percentile","points":3.74},{"name":"CVSS severity","points":5.46}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SINEC NMS","versions":["< V4.0 SP3"]},{"vendor":"Siemens","product":"User Management Component (UMC)","versions":["< V2.15.2.1"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2026-02-10T15:02:46.316399Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-6890","exploited":false,"provenance":"source"}}