{"id":"CVE-2026-3301","published":"2026-02-27T05:32:15Z","modified":"2026-02-27T18:53:12Z","title":"Totolink N300RH Web Management cstecgi.cgi setWebWlanIdx os command injection","vendor":"Totolink","product":"N300RH","tier":"tail","description":{"text":"A security flaw has been discovered in Totolink N300RH 6.1c.1353_B20190305. Affected by this vulnerability is the function setWebWlanIdx of the file /cgi-bin/cstecgi.cgi of the component Web Management Interface. Performing a manipulation of the argument webWlanIdx results in os command injection. The attack can be initiated remotely. The exploit has been released to the public and may be used for attacks.","provenance":"source","from":"CVE.org"},"cvss":{"score":9.8,"severity":"CRITICAL","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.04439,"percentile":0.91615,"provenance":"source"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"references":[{"url":"https://vuldb.com/?id.348052","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.348052","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.761297","tags":["third-party-advisory"]},{"url":"https://github.com/xyh4ck/iot_poc/blob/main/TOTOLINK/N300RHv4/01_setWebWlanIdx_RCE/README.md","tags":["exploit"]},{"url":"https://www.totolink.net/","tags":["product"]}],"priority":{"score":30.2,"factors":[{"name":"EPSS percentile","points":18.32},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":6.86}]},"vendorSlug":"totolink","affectedVersions":[{"vendor":"Totolink","product":"N300RH","versions":["6.1c.1353_B20190305"]}],"ssvc":{"exploitation":"poc","automatable":"yes","technicalImpact":"total","timestamp":"2026-02-27T18:53:02.851868Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"A flaw in the Web Management Interface of the Totolink N300RH router, within the setWebWlanIdx function of /cgi-bin/cstecgi.cgi, allows manipulation of the webWlanIdx argument that leads to OS command injection. An attacker can exploit it remotely without authentication or user interaction, by sending a crafted request to the web management interface over the network.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T00:18:46Z"},"euvd":{"id":"EUVD-2026-9003","exploited":false,"provenance":"source"},"exploitRefs":["https://github.com/xyh4ck/iot_poc/blob/main/TOTOLINK/N300RHv4/01_setWebWlanIdx_RCE/README.md"]}