{"id":"CVE-2026-42348","published":"2026-05-12T18:01:41Z","modified":"2026-05-13T19:32:28Z","title":"OpAMP client reads unbounded HTTP response bodies","vendor":"open-telemetry","product":"opentelemetry-dotnet-contrib","tier":"tail","description":{"text":"OpenTelemetry.OpAmp.Client is the OpAMP client for OpenTelemetry .NET. Prior to 0.2.0-alpha.1, when receiving responses from the OpAMP server over HTTP, the OpAMP client allocates an unbounded buffer to read all bytes from the server, with no upper-bound on the number of bytes consumed. This could cause memory exhaustion in the consuming application if the configured OpAMP server is attacker-controlled (or a network attacker can MitM the connection) and an extremely large body is returned in the response. This vulnerability is fixed in 0.2.0-alpha.1.","provenance":"source","from":"CVE.org"},"cvss":{"score":5.9,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00311,"percentile":0.24625,"provenance":"source"},"cwes":[{"id":"CWE-789","name":"Memory Allocation with Excessive Size Value"}],"references":[{"url":"https://github.com/open-telemetry/opentelemetry-dotnet-contrib/security/advisories/GHSA-w2jh-77fq-7gp8","tags":["x_refsource_CONFIRM"]},{"url":"https://github.com/open-telemetry/opentelemetry-dotnet-contrib/pull/4116","tags":["x_refsource_MISC"]}],"priority":{"score":9.1,"factors":[{"name":"EPSS percentile","points":4.92},{"name":"CVSS severity","points":4.13}]},"vendorSlug":"open-telemetry","affectedVersions":[{"vendor":"open-telemetry","product":"opentelemetry-dotnet-contrib","versions":["< 0.2.0-alpha.1"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2026-05-13T19:25:08.216390Z","from":"CISA ADP","provenance":"source"},"affected":[{"ecosystem":"NuGet","package":"OpenTelemetry.OpAmp.Client","vulnerableRanges":["<0.2.0-alpha.1"],"patched":["0.2.0-alpha.1"],"from":["GHSA-w2jh-77fq-7gp8"],"provenance":"source"}],"summary":{"text":"The OpAMP client in OpenTelemetry .NET (OpenTelemetry.OpAmp.Client, part of opentelemetry-dotnet-contrib) reads entire HTTP response bodies from the OpAMP server into an unbounded buffer, with no cap on how many bytes it consumes. An attacker who controls the configured OpAMP server, or who can man-in-the-middle the connection, can return an extremely large response body and exhaust memory in the consuming application; this requires no privileges or user interaction, but the attacker must be in a position to serve or intercept the OpAMP traffic.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-20T22:08:55Z"},"euvd":{"id":"EUVD-2026-29706","exploited":false,"provenance":"source"}}