{"id":"CVE-2026-46749","published":"2026-06-09T08:47:05Z","modified":"2026-06-09T13:10:31Z","title":"A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6)","vendor":"Siemens","product":"SINEC INS","tier":"tail","description":{"text":"A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The affected application uses a password hashing implementation with a static, hardcoded salt shared across all users and installations, and is configured with an insufficient number of iterations. This could allow an attacker to efficiently recover user passwords using brute-force or precomputed attacks, potentially resulting in unauthorized access.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.5,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00121,"percentile":0.01953,"provenance":"source"},"cwes":[{"id":"CWE-760","name":"Use of a One-Way Hash with a Predictable Salt"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-860189.html","tags":[]}],"priority":{"score":5.6,"factors":[{"name":"EPSS percentile","points":0.39},{"name":"CVSS severity","points":5.25}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SINEC INS","versions":["< V1.0 SP2 Update 6"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2026-06-09T13:10:22.511716Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-35386","exploited":false,"provenance":"source"}}