{"id":"CVE-2026-4937","published":"2026-08-19T20:11:01Z","modified":"2026-08-20T15:20:20Z","title":"Power System Insufficient Entropy","vendor":"IBM","product":"PowerVM Hypervisor","tier":"tail","description":{"text":"IBM PowerVM Hypervisor FW1110.00 through FW1110.20, FW1060.00 through FW1060.71, and FW950.00 through FW950.H2 could allow a local attacker with administrative privileges to decrypt encrypted data due to certain hypervisor calls utilizing less entropy than requested.","provenance":"source","from":"CVE.org"},"cvss":{"score":5.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:N/A:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00132,"percentile":0.02814,"provenance":"source"},"cwes":[{"id":"CWE-331","name":"Insufficient Entropy"}],"references":[{"url":"https://www.ibm.com/support/pages/node/7283900","tags":["vendor-advisory","patch"]}],"priority":{"score":4.3,"factors":[{"name":"EPSS percentile","points":0.56},{"name":"CVSS severity","points":3.71}]},"vendorSlug":"ibm","affectedVersions":[{"vendor":"IBM","product":"PowerVM Hypervisor","versions":[">= FW1110.00, <= FW1110.20",">= FW1060.00, <= FW1060.71",">= FW950.00, <= FW950.H2"]}],"solutions":{"items":["Customers with the products below should install FW1110.30(1110_125), FW1120.00(1120_159), or newer to remediate this vulnerability. Power 11 * IBM Power System E1180 (9080-HEU) Customers with the products below should install FW1110.30(1110_145), FW1120.00(1120_183), or newer to remediate this vulnerability. Power 11 * IBM Power System S1122 (9824-22A) * IBM Power System S1124 (9824-42A) * IBM Power System S1122s (9824-22B) * IBM Power System S1114 (9824-41B) * IBM Power System L1122 (9856-22H) * IBM Power System L1124 (9856-42H) * IBM Power System E1150 (9043-MRU) Customers with the products below should install FW1060.72(1060_171) / FW1060.80(1060_180), or newer to remediate this vulnerability. Power 10 * IBM Power System E1080 (9080-HEX) Customers with the products below should install FW1060.72(1060_177) / FW1060.80(1060_185), or newer to remediate this vulnerability. Power 10 * IBM Power System S1022 (9105-22A) * IBM Power System S1024 (9105-42A) * IBM Power System S1022s (9105-22B) * IBM Power System S1014 (9105-41B) * IBM Power System L1022 (9786-22H) * IBM Power System L1024 (9786-42H) * IBM Power System E1050 (9043-MRX) * IBM Power System S1012 (9028-21B) Customers with…"],"from":"CVE.org CNA","provenance":"source"},"workarounds":{"items":["Fully remediating this CVE requires administrators that have enabled Platform Keystore to take the following actions: * Reboot any partitions that have Platform Keystore enabled after updating firmware. * Regenerate all cryptographic keys that were generated by Platform Keystore on affected firmware versions, as those keys are considered weak."],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2026-08-20T14:18:54.835231Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-62842","exploited":false,"provenance":"source"}}