{"id":"CVE-2026-60073","published":"2026-07-16T20:22:36Z","modified":"2026-07-17T13:15:30Z","title":"AutomationDirect Productivity Suite Out-of-bounds Read","vendor":"AutomationDirect","product":"Productivity Suite","tier":"tail","description":{"text":"An out-of-bounds read in the Productivity Suite allows a physical \nattacker to control the length of data sent to a USB device. This can \nlead to a system crash or disclosure of kernel memory.","provenance":"source","from":"CVE.org"},"cvss":{"score":5.9,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00245,"percentile":0.16063,"provenance":"source"},"cwes":[{"id":"CWE-125","name":"Out-of-bounds Read"}],"references":[{"url":"https://www.automationdirect.com/support/software-downloads","tags":[]},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-197-04","tags":[]},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-197-04.json","tags":[]}],"priority":{"score":7.3,"factors":[{"name":"EPSS percentile","points":3.21},{"name":"CVSS severity","points":4.13}]},"vendorSlug":"automationdirect","affectedVersions":[{"vendor":"AutomationDirect","product":"Productivity Suite","versions":["<= v4.6.2.2"]}],"fixedVersions":[{"vendor":"AutomationDirect","product":"Productivity Suite","versions":["v4.7.0.47"]}],"solutions":{"items":["AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads"],"from":"CVE.org CNA","provenance":"source"},"workarounds":{"items":["If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. * Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. * Use only trusted, dedicated internal networks or air-gapped systems for device communication. * Restrict both physical and logical access to authorized personnel only. * Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. * Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. * Enable and regularly review system logs to detect suspicious or unauthorized activity. * Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. * Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly."],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2026-07-17T13:15:13.008365Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-45036","exploited":false,"provenance":"source"}}