{"id":"CVE-2026-81305","published":"2026-09-18T16:12:32Z","modified":"2026-09-19T14:11:43Z","title":"CareCam CM2507 Inclusion of Functionality from Untrusted Control Sphere","vendor":"CareCam","product":"HMT.CM2507 Firmware","tier":"tail","description":{"text":"CM2507 IP cameras automatically execute a predetermined script from removable media without verifying its authenticity or integrity. An attacker with physical access to the device could supply a malicious script and execute arbitrary code in the security context of the affected device.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.8,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00278,"percentile":0.12902,"provenance":"source"},"cwes":[{"id":"CWE-829","name":"Inclusion of Functionality from Untrusted Control Sphere"}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-08","tags":[]},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-08.json","tags":[]}],"priority":{"score":7.3,"factors":[{"name":"EPSS percentile","points":2.58},{"name":"CVSS severity","points":4.76}]},"vendorSlug":"carecam","affectedVersions":[{"vendor":"CareCam","product":"HMT.CM2507 Firmware","versions":["v251211.1507"]}],"workarounds":{"items":["CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information."],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2026-09-19T13:44:14.619574Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-83044","exploited":false,"provenance":"source"}}