{"id":"CVE-2026-82948","published":"2026-11-19T10:30:43Z","modified":"2026-11-19T15:10:24Z","title":"RF Replay of control commands","vendor":"Onyx Cookware ApS","product":"Nexsmart Guardian 2 (Alarm system)","tier":"tail","description":{"text":"The Guardian 2 alarm unit lacks a mechanism to\nauthenticate control commands sent over 433.92 MHz, which allows an attacker to\nreplay the static commands to impersonate activity.  The attacker can also disarm or arm the\nsystem at will if a Nexsmart keypad (product link) is in use, thus compromising\nthe functionality of the alarm system completely.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.1,"severity":"HIGH","version":"4.0","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00207,"percentile":0.10966,"provenance":"source"},"cwes":[{"id":"CWE-294","name":"Authentication Bypass by Capture-replay"}],"references":[{"url":"https://medium.com/@enalindstrom/learning-iot-security-with-the-nexsmart-guardian-2-8028d55c430c","tags":[]}],"priority":{"score":7.2,"factors":[{"name":"EPSS percentile","points":2.19},{"name":"CVSS severity","points":4.97}]},"vendorSlug":"onyx-cookware-aps","affectedVersions":[{"vendor":"Onyx Cookware ApS","product":"Nexsmart Guardian 2 (Alarm system)","versions":["0"]}],"solutions":{"items":["Nexsmart reported suspending sales and described a phase-out of the current Guardian models. If you own an affected system and are concerned, contact Nexsmart through its official support channels and ask about any current remediation guidance."],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2026-11-19T15:10:15.653657Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-129654","exploited":false,"provenance":"source"}}