{"id":"CVE-2026-8359","published":"2026-05-27T19:49:18Z","modified":"2026-05-27T20:26:19Z","title":"Gladinet Triofox WOSHttpStatusModule.dll NULL Function Pointer Call DoS","vendor":"Gladinet","product":"Triofox","tier":"tail","description":{"text":"When processing a request with a URL path starting with /status or /sysinfo, WOSHttpStatusModule.dll is to be loaded to handle such URL patterns. The WOSBin_LoadHttpModule function in the dll would be called to set up a \"module\" object for that module. However, WOSHttpStatusModule.dll is not present in the installation. As a result, a function pointer to WOSBin_LoadHttpModule (which would have been in the export table in WOSHttpStatusModule.dll) is set to NULL, resulting in calling a function at address 0.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.5,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00337,"percentile":0.27839,"provenance":"source"},"cwes":[{"id":"CWE-476","name":"NULL Pointer Dereference"}],"references":[{"url":"https://www.tenable.com/security/research/TRA-2026-45","tags":[]}],"priority":{"score":10.8,"factors":[{"name":"EPSS percentile","points":5.57},{"name":"CVSS severity","points":5.25}]},"vendorSlug":"gladinet","affectedVersions":[{"vendor":"Gladinet","product":"Triofox","versions":["< 17.3.10565.57509"]}],"capec":[{"id":"CAPEC-129","name":"Pointer Manipulation"}],"ssvc":{"exploitation":"poc","automatable":"yes","technicalImpact":"partial","timestamp":"2026-05-27T20:26:08.783283Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-32646","exploited":false,"provenance":"source"}}