{"id":"CVE-2026-86299","published":"2026-09-07T11:15:07Z","modified":"2026-09-11T20:35:08Z","title":"Linksys RE7000 PingTest json.cgi platform_event_pingTest os command injection","vendor":"Linksys","product":"RE7000","tier":"tail","description":{"text":"A vulnerability was detected in Linksys RE7000 2.0.15. This affects the function platform_event_pingTest of the file /cgi-bin/json.cgi?PingTest of the component PingTest Handler. The manipulation of the argument pingTestIp/pingTestPktSize/pingTestTimes results in os command injection. The attack can be launched remotely. The exploit is now public and may be used.","provenance":"source","from":"CVE.org"},"cvss":{"score":9.9,"severity":"CRITICAL","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.0374,"percentile":0.90111,"provenance":"source"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"references":[{"url":"https://vuldb.com/vuln/399463","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/vuln/399463/cti","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/cve/CVE-2026-86299","tags":["third-party-advisory"]},{"url":"https://vuldb.com/submit/906547","tags":["third-party-advisory"]},{"url":"https://github.com/limou89/somevul/blob/main/Linksys_RE7000_v2_PingTest_Command_Injection.md","tags":["exploit"]},{"url":"https://www.linksys.com/","tags":["product"]}],"priority":{"score":30.0,"factors":[{"name":"EPSS percentile","points":18.02},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":6.93}]},"vendorSlug":"linksys","affectedVersions":[{"vendor":"Linksys","product":"RE7000","versions":["2.0.15"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"total","timestamp":"2026-09-11T20:15:44.006697Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"A command injection flaw exists in the platform_event_pingTest function of the PingTest Handler component in the Linksys RE7000 (version 2.0.15), reachable through the /cgi-bin/json.cgi?PingTest endpoint, where the pingTestIp, pingTestPktSize and pingTestTimes arguments are not properly neutralised before being used in an OS command. An attacker with low privileges can exploit this remotely over the network, without user interaction, to inject and run arbitrary operating system commands on the device.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:02:16Z"},"euvd":{"id":"EUVD-2026-72349","exploited":false,"provenance":"source"},"exploitRefs":["https://github.com/limou89/somevul/blob/main/Linksys_RE7000_v2_PingTest_Command_Injection.md"]}