{"id":"CVE-2026-89208","published":"2026-10-13T09:19:12Z","modified":"2026-10-13T16:20:06Z","title":"A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic…","vendor":"Siemens","product":"Capital Embedded AR Classic 431-422","tier":"tail","description":{"text":"A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Desigo PXC00-E.D (All versions >= V2.3), Desigo PXC00-U (All versions >= V2.3), Desigo PXC001-E.D (All versions >= V2.3), Desigo PXC100-E.D (All versions >= V2.3), Desigo PXC12-E.D (All versions >= V2.3), Desigo PXC128-U (All versions >= V2.3), Desigo PXC200-E.D (All versions >= V2.3), Desigo PXC22-E.D (All versions >= V2.3), Desigo PXC22.1-E.D (All versions >= V2.3), Desigo PXC36.1-E.D (All versions >= V2.3), Desigo PXC50-E.D (All versions >= V2.3), Desigo PXC64-U (All versions >= V2.3), Desigo PXM20-E (All versions >= V2.3). The affected product does not properly validate input bounds before accessing packet data. This could allow an unauthenticated remote attacker to trigger memory reads outside the intended packet boundaries.","provenance":"source","from":"CVE.org"},"cvss":{"score":5.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00262,"percentile":0.18337,"provenance":"source"},"cwes":[{"id":"CWE-125","name":"Out-of-bounds Read"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-055299.html","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-333035.html","tags":[]}],"priority":{"score":7.4,"factors":[{"name":"EPSS percentile","points":3.67},{"name":"CVSS severity","points":3.71}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"Capital Embedded AR Classic 431-422","versions":["all versions"]},{"vendor":"Siemens","product":"Capital Embedded AR Classic R20-11","versions":["< V2303"]},{"vendor":"Siemens","product":"Desigo PXC00-E.D","versions":[">= V2.3"]},{"vendor":"Siemens","product":"Desigo PXC00-U","versions":[">= V2.3"]},{"vendor":"Siemens","product":"Desigo PXC001-E.D","versions":[">= V2.3"]},{"vendor":"Siemens","product":"Desigo PXC100-E.D","versions":[">= V2.3"]},{"vendor":"Siemens","product":"Desigo PXC12-E.D","versions":[">= V2.3"]},{"vendor":"Siemens","product":"Desigo PXC128-U","versions":[">= V2.3"]},{"vendor":"Siemens","product":"Desigo PXC200-E.D","versions":[">= V2.3"]},{"vendor":"Siemens","product":"Desigo PXC22-E.D","versions":[">= V2.3"]}],"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial","timestamp":"2026-10-13T15:48:47.827643Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-98405","exploited":false,"provenance":"source"}}