{"id":"CVE-2026-9514","published":"2026-05-25T22:45:09Z","modified":"2026-05-26T12:34:49Z","title":"Totolink CA750-PoE Setting cstecgi.cgi setNetworkDiag os command injection","vendor":"Totolink","product":"CA750-PoE","tier":"tail","description":{"text":"A security vulnerability has been detected in Totolink CA750-PoE 6.2c.510. Impacted is the function setNetworkDiag of the file /cgi-bin/cstecgi.cgi of the component Setting Handler. The manipulation of the argument NetDiagHost/NetDiagPingNum/NetDiagPingSize/NetDiagPingTimeOut/NetDiagTracertHop is directly passed by the attacker/so we can control the NetDiagHost/NetDiagPingNum/NetDiagPingSize/NetDiagPingTimeOut/NetDiagTracertHop leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.10375,"percentile":0.95835,"provenance":"source"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"references":[{"url":"https://vuldb.com/vuln/365514","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/vuln/365514/cti","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/submit/813926","tags":["third-party-advisory"]},{"url":"https://github.com/wudipjq/my_vuln/blob/main/totolink4/vuln_52/52.md","tags":["exploit"]},{"url":"https://www.totolink.net/","tags":["product"]}],"priority":{"score":28.6,"factors":[{"name":"EPSS percentile","points":19.17},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":4.41}]},"vendorSlug":"totolink","affectedVersions":[{"vendor":"Totolink","product":"CA750-PoE","versions":["6.2c.510"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2026-05-26T12:34:33.434975Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"A command injection flaw exists in the setNetworkDiag function of /cgi-bin/cstecgi.cgi, in the Setting Handler component of the Totolink CA750-PoE 6.2c.510 product, where the NetDiagHost, NetDiagPingNum, NetDiagPingSize, NetDiagPingTimeOut and NetDiagTracertHop arguments are passed to the OS without neutralisation. An attacker with the ability to reach the device over the network, with low-privilege authentication, and without any required user interaction can inject operating system commands through these arguments.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:18:14Z"},"euvd":{"id":"EUVD-2026-31752","exploited":false,"provenance":"source"},"exploitRefs":["https://github.com/wudipjq/my_vuln/blob/main/totolink4/vuln_52/52.md"]}