FLIR Thermal Camera PT-Series firmware version 8.0.0.64 Unauthenticated Remote Command Injection
No fixed version listed yet.Check the vendor advisory. References ↓
FLIR Systems, Inc. · FLIR Thermal Camera PT-Series
The FLIR Thermal Camera PT-Series firmware version 8.0.0.64 contains multiple command injection flaws in the controllerFlirSystem.php script, specifically in the execFlirSystem() function, where unsanitized POST parameters are passed to shell_exec(). An attacker who can reach the device over the network can execute arbitrary system commands as root, without authentication or user interaction, and no special configuration is required.
Official description · CVE.org
FLIR Thermal Camera PT-Series firmware version 8.0.0.64 contains multiple unauthenticated remote command injection vulnerabilities in the controllerFlirSystem.php script. Attackers can execute arbitrary system commands as root by exploiting unsanitized POST parameters in the execFlirSystem() function through shell_exec() calls. Exploitation evidence was observed by the Shadowserver Foundation on 2026-01-06 (UTC).
- Exploited
- Yes, in VulnCheck KEV
- Reports
- 0
- Tactics
- 0/15
Exploitation timelineDated milestones for a CVE: when it was disclosed, when exploit code became public, when exploitation was confirmed, and when threat reports named it.
First seen exploited the day it was disclosed.
Affected versions and fixes
as published in the CVE recordFLIR Systems, Inc. FLIR Thermal Camera PT-Series
Affected: 8.0.0.64