Tenda N300 F3 12.01.01.48 devices allow remote attackers to obtain sensitive information (possibly including an…
No fixed version listed yet.Check the vendor advisory. References ↓
The Tenda N300 F3 router, firmware version 12.01.01.48, exposes a configuration download endpoint (cgi-bin/DownloadCfg/RouterCfm.cfg) that can leak sensitive data, possibly including an http_passwd entry. An attacker with network access to the device can exploit this by sending a direct, unauthenticated HTTP request to that path, with no user interaction or special configuration needed, though the report also notes that a trailing "?" or unusual request headers may be required and the reason for this is unclear.
Official description · CVE.org
Tenda N300 F3 12.01.01.48 devices allow remote attackers to obtain sensitive information (possibly including an http_passwd line) via a direct request for cgi-bin/DownloadCfg/RouterCfm.cfg, a related issue to CVE-2017-14942. NOTE: the vulnerability report may suggest that either a ? character must be placed after the RouterCfm.cfg filename, or that the HTTP request headers must be unusual, but it is not known why these are relevant to the device's HTTP response behavior.
- Exploited
- Yes, in VulnCheck KEV
- Reports
- 0
- Tactics
- 0/15
Exploitation timelineDated milestones for a CVE: when it was disclosed, when exploit code became public, when exploitation was confirmed, and when threat reports named it.
First seen exploited 4 years after disclosure. Public exploit code (PoC-in-GitHub) appeared 2 years after disclosure.
- Disclosedday 0
- Public exploit codePoC-in-GitHub+2 yrs
- First seen exploitedVulnCheck KEV evidence+4 yrs
Patch historyEarlier and later CVEs in the same code, in date order. It shows when a fix was bypassed or incomplete and which version finally fixed it.
2 related vulnerabilities in the same code over 3 years.
Linked vulnerabilitiesLinked by evidence that a fix failed or the same code was patched again. Oldest first.
relatedLow
Why these are linked: Link confidenceHow strong the evidence is that two CVEs are related. High: stated in the CVE text or linked in an advisory, or the same code was patched one release apart. Medium: the same code, or a version step plus a similar description. Low: similar description only.
- Stated in the CVE text
Tenda N300 F3 12.01.01.48 devices allow remote attackers to obtain sensitive information (possibly including an http_passwd line) via a direct request for cgi-bin/DownloadCfg/RouterCfm.cfg, a related issue to CVE-2017-14942.
This CVECVE-2020-35391Tenda N300 F3 12.01.01.48 devices allow remote attackers to…1 Jan 2021- Stated in the CVE text
What security researchers reported
Not named in any threat report yetAlso mentioned in 5 community threat pulses (AlienVault OTX)
Weaker evidencePulses are indicator collections that anyone can publish. A mention is not confirmation of exploitation.
- NCSC Advisory - 18th Sept 2024 - PRC Botnet14 Jan 2025
- People's Republic of China-Linked Actors Compromise Routers and IoT Devices for Botnet Operations7 Jan 2025
- People's Republic of China-Linked Actors Compromise Routers and IoT Devices for Botnet Operations7 Jan 2025
- People's Republic of China-Linked Actors Compromise Routers and IoT Devices for Botnet Operations2 Oct 2024
- CSA-PRC-LINKED-ACTORS-BOTNET19 Sep 2024