AutomationDirect DirectLOGIC with Serial Communication Cleartext Transmission
Fix:see the vendor's fix instructions Instructions ↓
AutomationDirect · DirectLOGIC D0-06 series CPUs
AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;
- Exploited
- Yes, in VulnCheck KEV
- Reports
- 0
- Tactics
- 0/15
Exploitation timelineDated milestones for a CVE: when it was disclosed, when exploit code became public, when exploitation was confirmed, and when threat reports named it.
First seen exploited 48 days before it was disclosed.
- First seen exploitedVulnCheck KEV evidence48 days before
- Disclosedday 0
Affected versions and fixes
as published in the CVE recordAutomationDirect DirectLOGIC D0-06 series CPUs
Affected: >= D0-06DD1, < 2.72 · >= D0-06DD2, < 2.72 · >= D0-06DR, < 2.72 · >= D0-06DA, < 2.72 · >= D0-06AR, < 2.72 · >= D0-06AA, < 2.72 · >= D0-06DD1-D, < 2.72 · >= D0-06DD2-D, < 2.72 · >= D0-06DR-D, < 2.72
Fix
AutomationDirect recommends users upgrade to firmware Version 2.72 or later, which will no longer respond with the password when requested with the specially crafted message. Additional mitigation for brute force password access has also been added. Three incorrect password entries will result in a 3-hour lock out of password entry. Power cycle will allow subsequent password attempts. While automation networks and systems have built-in password protection schemes, this is only one step in securing the affected systems. Automation control system networks must incorporate data protection and security measures at least as robust as a typical business computer system. AutomationDirect recommends users of PLCs, HMI products, and other SCADA system products perform independent network security analysis to determine the proper level of security required for the application. AutomationDirect has identified the specific mitigation actions listed below: Secure physical access. Isolate and air gap networks when possible. Consider some of the AutomationDirect newer PLC families.
What security researchers reported
Not named in any threat report yetAlso mentioned in 2 community threat pulses (AlienVault OTX)
Weaker evidencePulses are indicator collections that anyone can publish. A mention is not confirmation of exploitation.