{"version":"https://jsonfeed.org/version/1.1","title":"Patchfirst: Schneider Electric vulnerabilities","home_page_url":"https://patchfirst.co/vendor/schneider-electric/","feed_url":"https://patchfirst.co/feed/vendor/schneider-electric.json","description":"New and newly exploited Schneider Electric CVEs, with CISA KEV, EPSS and ATT&CK context. Newest 50 by publication or KEV listing.","language":"en-GB","items":[{"id":"CVE-2024-5559","url":"https://patchfirst.co/cve/CVE-2024-5559/","title":"CVE-2024-5559: CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists that could cause denial of service…","content_text":"Schneider Electric · PowerLogic P5. Not in CISA KEV. EPSS 0.2% (higher than 7.7% of CVEs). CVSS 6.1 MEDIUM. Named in 1 threat report. Priority 11.0 of 100.","summary":"CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists that could cause denial of service…","date_published":"2024-06-12T00:00:00.000Z","date_modified":"2024-08-01T21:18:06.000Z","tags":[],"_patchfirst":{"reason":"published","priority":11,"kev":null,"epss":{"score":0.00181,"percentile":0.07696},"cvss":{"score":6.1,"severity":"MEDIUM","version":"3.1"},"vendor":"Schneider Electric","product":"PowerLogic P5","techniqueIds":[],"reportCount":1,"hasPublicExploit":false,"euvdExploited":false}},{"id":"CVE-2022-34753","url":"https://patchfirst.co/cve/CVE-2022-34753/","title":"CVE-2022-34753: A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability…","content_text":"Schneider Electric · SpaceLogic C-Bus Home Controller. Not in CISA KEV. EPSS 70.5% (higher than 99.39% of CVEs). CVSS 8.8 HIGH. Public exploit code exists. Priority 66.7 of 100.","summary":"A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability…","date_published":"2022-07-13T00:00:00.000Z","date_modified":"2024-09-16T19:14:26.000Z","tags":["public-exploit"],"_patchfirst":{"reason":"published","priority":66.7,"kev":null,"epss":{"score":0.7048,"percentile":0.99388},"cvss":{"score":8.8,"severity":"HIGH","version":"3.1"},"vendor":"Schneider Electric","product":"SpaceLogic C-Bus Home Controller","techniqueIds":[],"reportCount":0,"hasPublicExploit":true,"euvdExploited":false}},{"id":"CVE-2018-7841#kev","url":"https://patchfirst.co/cve/CVE-2018-7841/","title":"[KEV] CVE-2018-7841: Schneider Electric U.motion Builder SQL Injection Vulnerability","content_text":"Schneider Electric · U.motion Builder. In CISA KEV since 2022-04-15. ENISA EUVD lists it as exploited. EPSS 72.5% (higher than 99.44% of CVEs). CVSS 9.8 CRITICAL. Public exploit code exists. ATT&CK: T1190 Exploit Public-Facing Application; T1059 Command and Scripting Interpreter. Priority 69.7 of 100.","summary":"Schneider Electric U.motion Builder SQL Injection Vulnerability","date_published":"2022-04-15T00:00:00.000Z","date_modified":"2026-06-17T02:03:50.000Z","tags":["kev","public-exploit","T1190","T1059"],"_patchfirst":{"reason":"kev","priority":69.7,"kev":{"dateAdded":"2022-04-15","ransomware":false},"epss":{"score":0.72486,"percentile":0.99439},"cvss":{"score":9.8,"severity":"CRITICAL","version":"3.1"},"vendor":"Schneider Electric","product":"U.motion Builder","techniqueIds":["T1190","T1059"],"reportCount":0,"hasPublicExploit":true,"euvdExploited":true}},{"id":"CVE-2018-8872","url":"https://patchfirst.co/cve/CVE-2018-8872/","title":"CVE-2018-8872: In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from…","content_text":"Schneider Electric · Triconex Tricon. Not in CISA KEV. EPSS 2.2% (higher than 82.5% of CVEs). Named in 1 threat report. Priority 55.4 of 100.","summary":"In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from…","date_published":"2018-05-04T00:00:00.000Z","date_modified":"2024-09-16T16:32:36.000Z","tags":[],"_patchfirst":{"reason":"published","priority":55.4,"kev":null,"epss":{"score":0.02204,"percentile":0.82531},"cvss":null,"vendor":"Schneider Electric","product":"Triconex Tricon","techniqueIds":[],"reportCount":1,"hasPublicExploit":false,"euvdExploited":false}},{"id":"CVE-2018-7522","url":"https://patchfirst.co/cve/CVE-2018-7522/","title":"CVE-2018-7522: In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers…","content_text":"Schneider Electric · Triconex Tricon. Not in CISA KEV. EPSS 0.4% (higher than 36% of CVEs). Priority 42.2 of 100.","summary":"In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers…","date_published":"2018-05-04T00:00:00.000Z","date_modified":"2024-09-17T00:02:25.000Z","tags":[],"_patchfirst":{"reason":"published","priority":42.2,"kev":null,"epss":{"score":0.00417,"percentile":0.35974},"cvss":null,"vendor":"Schneider Electric","product":"Triconex Tricon","techniqueIds":[],"reportCount":0,"hasPublicExploit":false,"euvdExploited":false}}]}